ZS5062 / ZS5122 [ SPEAKER ZONE SELECTOR ]
ZS5062
|
ZS5122
|
|
Operating voltage |
24V DC via PS9400 adaptor
|
|
Power consumption (idle) |
3.29W
|
6.25W
|
Power consumption (All Call) |
0.72W
|
0.96W
|
Current consumption (idle) |
0.14A
|
0.26A
|
Current consumption (All Call) |
0.03A
|
0.04A
|
Max load / channel |
500W at 100V line
|
|
Number of zones |
6
|
12
|
Amplifier inputs |
6
|
12
|
Zone selection |
Front panel switch and remote
|
|
Cascade limitation |
16
|
|
Remote triggering |
-ve triggered (common ground)
|
|
Indicators |
Individual zone switch, Priority
|
|
Data communication |
RS485 19.2 kbps baud rate
|
|
Switching mode |
Individual, All Call
Local zone selection bypassed when remote trigger is activated |
|
Dimension (WxHxD) |
482 x 44 x 180 mm
|
|
Weight |
1.85 kg
|
2 kg
|